De Reclame, November 1925 – page 35
- Magazine
- De Reclame
- Issue date
- November 1925
- Page
- 35
- Department
- Magazines and journals
- Object number
- DRE_1925-11-01_p35
Text on this page (OCR)
847 E — 15-8-'25
Don’t feel lonesome
use Philips“Miniwatt”
Wireless Valves.
When living in an isolated district
the users of a radio receiving set, -
fitted with Philips valves, have
the pleasures of large cities within
reach. Even wearied townsfolk
need not leave their houses in
search of good entertainment,
since Radio makes it possible for
them to comfortably listen in
at home.
Philips “Miniwatt'’ Valves are
guaranteed to give joy and satis-
faction, because of the high vacuum
and the special filament used,
which ensure uniform operating
characteristics and an exceptio-
nally quiet performance, free from
any valve noises, common to
inferior makes.
One of the outstanding features of
the “Miniwatt'’ Valves described
here, is their extremely low fila-
ment current of not more than
0.06 AMPERES.
Type A #10 is an improved high
vacuum valve suitable for detec-
tion, audio frequency (LE) and
radiofrequency (HF) amplification.
Type A 406 is a very good
detector, but especially designed
for audio frequency (LF) ampli-
fication.
Both these valves should be
operated from a 4-volt storage
battery, as the required filament
tension ranges from 3.4-4 volt.
A filament resistance of 12 ohms
or more is necessary to obtain
the best results. Note should be
taken however, not to apply a
higher filament voltage than ab-
solutely required for good results,
and never to exceed the maximum
voltage as stated on the valves.
Types A 110 and A 106 are iden-
tical to A 410 and A 406 res-
pectively, as regards working
characteristics, but they are con-
structed to be operated from one
single dry-cell as the required vol-
tage ranges from 1.0 to 1.3 volts.
This feature deserves special con-
sideration in cases where storage
battery charging facilities are not
available.
On multi-stage receiving devices
each valve should be provided
with a separate dry cell, in order
to obtain a constant current
supply. Filament resistances of 12
ohms should be applied to get
best working results with both
types.
Philips “Miniwatt’ Valves are
supplied with standard caps but
can on request be fitted with any
type of cap wanted.
NEGATIVE GRID BIAS
AND PLATE VOLTAGE.
Philips “Miniwatt” Valves A 410 and
A 110 used as detectors on Broad-
casting wavelengths from 500 to 5000
metres, will give best results when
using: a grid condenser of:
0.0002—0.0003 mfd.,
and with a grid leak of:
1—5 megohms.
The plate voltage need not exceed
40 volts.
Used as audio frequency (LF) am-
plifiers they give the greatest satis-
faction with a negative grid bias, the
correct voltages being:
1/> volts at 80 volts plate voltage.
ez
3 volts at 100 volts plate voltage.
Philips “Miniwatt” A 406 and A 106
used as detectors on Broadcasting
Wavelengths as mentioned above, give
equally good results with the same
application of grid condenser and grid
leak as required for the A {10 and
A 110.
Used as audio frequency (LF) am-
plifiers they give the best reproduc-
tion ot speach or music, when the
following grid bias is applied:
3—4.5 volts at 60 volts plate voltage
4.5—6 volts at 80 volts plate voltage
6—9 volts at 100 volts plate voltage
HOW TO APPLY A
NEGATIVE GRID BIAS.
The grid of the amplifier valve is
connected to the “Secondary Outlet”
of the audio frequency (LF) frans-
former, whilst the “secondary inlet”
has to be connected to the negative
pole of the grid bias dry-cell battery
and the plus pole of that battery to
the negative side of the filament.
For exact grid bias voltages, consult
given data.