Tabel No. 21.
Warmtehoeveelheid, geleverd
door een buis van 1 M.
lengte, bij gegeven drukverlies.
Warmteuitstraling per uur, in Cal.
Buiswijdte in mM. 9.5 127 19 25.4 Poi NN
Eng. dm. 5/. 1/, 2 l Le
I 400 755 1686 3094 6352
Í 2 504 951 2125 3900 So06
3 093 1307 2920 5300 IT IOOO0
D 7 Soo TSO 3372 6184 12700
bo 5 895 1687 3769 6919 14200
Ke 6 980 1848 4129 7597 15560
5 7 Io58 1996 4460 8187 16810
a 8 1131 2134 4768 8752 17970
GE, fo) 1200 2263 5057 9283 19060
as) Io 1265 2396 5331 9785 20090
ie II 1328 2504 5594 10510 21080
a) 12 1368 2613 5840 10720 22000
5 13 1442 2720 6078 11160 22900
sie ae 1497 2823 6307 11580 23770
ei ITG 1549 2922 6529 11980 24600
5 20 1789 3374 7539 13840 28410
à& | 25 2000 3712 8429 15470 31760
rK 30 2191 4132 9233 16950 35010
/ 35 2367 4464 9973 18310 | 37580
El 40 2530 4 772 106600 19570 40170
el 45 20659 4946 11200 20570 12240
6 50 2829 5310 11920 21980 44920
ge 55 2907 5595 12500 22950 47 110
2 60 3099 5844 13060 23970 49200
E 65 3225 6082 13500 24950 SI2I10
IS 70 3347 6312 14100 25890 53150
So 3579 6748 15080 27680 56810
Qo 3795 7157 15990 29700 60260
Too 4000 7545 16860 30940 03520
door den stoominvoer in de kachels geen hinderlijk ge-
luid ontstaan kan. Een druk van 100 tot 300 K.G. per
M?. (0,01 tot 0,03 Atm.) is normaal daarvoor en het ver-
dient aanbeveling ervoor te zorgen, dat deze druk bij alle
kachels gelijk is.
Bij bovenstaande stoomspanning kan men rekenen, dat
een afsluiter van 13 m.M. voor 35CO Cal.
» > » 20 > > 8000 >»
» » 20m. so 200005
warmteuitstraling per uur door de stoomkachel vol-
doende is.
Het toe te laten spanningsverlies p;, — ps is nu door
bovenstaande cijfers bepaald en mag in geen gedeelte der
leiding overschreden worden.
3eschouwen wij het leidingsschema fig. 27, dan is
klaarblijkelijk de langste leidiog die van den ketel naar
kachel TI; ze bestaat uit de secties 1, 2 en 4. Men neemt
nu aan, dat het drukverlies p; — ps gelijkmatig over de
geheele buislengte verdeeld is.
Noemt men de totale lengte l en de lengte van de
sectie 1 l,, dan is de druk bij B
(Pp; — P») h 40)
p= Pi Ì
p is dan de druk, waarmede de stoom in de vertakking
naar de secties 5, 6, 7, 8, 9 en 10 stroomt. Van dit af-
takkingspunt tot de kachel III mag dan bijv. het druk
verlies niet grooter dan p — p; zijn.
Voor bekorting der berekening is volgens formule (39)
Tabel no. 21 berekend.
Voor het gebruik van deze tabel merken wij het vol-
gende op.
Is een buis 20 M. lang, moet ze 20000 Cal. per uur
doorlaten, zij p, == 1000 K.G. per M?. en p‚ 200 K.G. per
M?, dan is de drukverlaging op 1 Meter buislengte
en WOE 0 KE. per M.
38 | 44,4 | 50.7 | 57,1| 63.4 | 09.8 | 76.1 | 82.5 | 88.8
1 a 13/, 2 2, Dii 23/, 3 38, | 31/
Q241 11590 TOO4O0 32130 41000 50350 62770 74700
LIO5O| 140IO| 20220| 33130 | 45440 | 57980 | 71210 { 88760 | 105600
16010 | 20080| 27780| 42490 | 55650| 71oro| 87210 lo87oo | 129400
18480 | 23190 | 32080 | 49060 | 64260 | 819go | 100700 | 125500 | 149500
20660 25920 35970 54850 71860 916070 LI2500 143000 | 169700
22640 | 28290 | 39290 | 60080 | 78720 | T00400 | 123400 | 153700 | 183000
24450 30070 42440 64900 S5oro 108000 133200 | 166000 197 500
26080 | 32790 | 45370 | 69380 } 90880 | 115900 | 142400 | 177500 | 211300
27720 | 35590| 48120 | 73580 | 96390 | 123000 | 151100 | 188300 | 224100
29220 360660 50730 77579 | ToIboo | 129600 | 159200 | 196goo | 236300
30660 | 38470 81400 | 105400 | 136000 | 167100 | 208300 | 248000
32010 | 40160 84970 | 110000 | 142000 | 174400 | 217400 | 258900
33320 | 41800 88440 | 115800 | 147800 | 181500 | 226300 | 269400
34420 | 43380 | 60020 | 91780 | 120200 | 153400 | 188400 | 234800 | 279600
go 44900 62130 94890 | 124400 158700 195100 | 243100 289400
41330 | 51840 | 71740 | 109700 | 143700 | 183300
225200 | 280700 | 334100
46200 | 56680 | 80210 | 122600 | 160600
1700 313800 373000
5o6ro | 63500 | 87860 | 134300 | 174000 | 224500 275900 | 343700 | 409300
54070 68580 94900 145 TOO Keron Kele) 242500 297900 307 100 442100
58450 | 73320 | TOI5OO | 155100 | 203200 | 259300 | 318500 | 397000 | 472600
01420 77950 | TO6600 | 164500 | 215500 | 275000 | 337400 | 421000 | 501300
65340 | 81980 | 113400 | 173400 | 227200 | 289900 | 356100 | 443800 528400
68530 | 85970 | 119OoO | 181goo | 238300 | 304000 | 373500 465400 | 554200
395 55
71580 89800 | 124200 | 190000 | 248900 317600 | 390100 | 486100 578800
745 00 93400 129300 | 197700 259000 330500 405900 5006000 602500
77320|\ 96990 | 134200 | 205200 268800 343000 | 421300 | 525100 | 625200
826 50| 103700 | 143500 | 219400 | 287400 | 366700 | 450300 | 561400 668 J00
976 70| 110000 152200 22600 304800 388900 177700 | 595400 708900
92410 II59go0 160400
e)
>
45300 | 321300 | 410000 | 503500 | 27700 | 747000
Volgens deze tabel levert bij deze drukverlaging een
buis van 1 Eng. duim wijd 19570, een buis van 1!/, Eng.
duim wijd 40170 Cal. Meu moet dus de laatstgenoemde
kiezen.
Is het verschil tusschen de vereischte en de volgens
de tabel door een buis over te brengen warmtehoeveel-
heid slechts gering, dan kan men zekerheidshalve een
verwijding van de buis tot de volgende handelsmaat ne-
men. Bij zeer korte buisgedeelten, waarin slechts weinig
krommingen e.d. weerstand veroorzakende factoren aan-
wezig zijn, kan men intusschen van wijdere buizen afzien.
Acht men de langs dezen weg verkregen cijfers niet
betrouwbaar genoeg, maar wil men zich vergewissen, welk
drukverlies inderdaad in het geheele leidingsnet ontstaat,
dan moet men het met gegeven buiswijdten overeenko-
mende drukverlies met behulp van formule (35: bepalen
en voor een der leidingsecties het verschil tusschen de
zoo berekende p‚ en de in werkelijkheid verlangde sub-
stitueeren en daarna d berekenen. Men gaat dus te werk
als in $ 35 aangegeven is.
De buizen, welke voor afvoer van het condensatie-wa-
ter der stoomkachels dienen en tevens de lucht daaruit
moeten afvoeren (condensleidingen) worden bij loodrech-
ten stand dezer buizen 0,5 maal en bij horizontalen stand
0,7 maal zoo wijd als de bijbehoorende stoomtoevoerlei-
dingen. In de practijk gaat men echter daarmede niet
gaarne beneden een inw. diameter van %/ tot !/, Eng.
duim.
8 38. Verwarming door afgewerkten stoom
Ten slotte vermelden wij nog bovenstaand verwarmings-
systeem, dat zoowel in fabrieken, als in groote gebouwen
waar stoommachines opgesteld zijn, voorkomt. De afge-
werkte stoom der stoommachine mag slechts een span-
ning van 0,1 tot hoogstens 0,2 Atm. overdruk hebben,
opdat de machine. geen te hoogen terugdruk op den zuiger